SMF Type 2 RecordThis table shows the record layout for type 2 SMF records
|
It's easy to report on SMF 2 data! | |
Spectrum SMF Writer handles the difficult SMF record parsing for you automatically. You just specify which fields you want to see. Spectrum SMF Writer also converts the arcane date and time fields and reformats them into an attractive report. Plus, Spectrum SMF Writer can export SMF data as comma delimited files to use on your PC.
|
Offset (Dec.) | Offset (Hex) | Name | Length | Format | Description |
0 | 0 | SMF2LEN | 2 | binary | Record length. This field and the next field (total of four bytes) form the RDW (record descriptor word). See “Standard SMF Record Header” on page 13-1 for a detailed description.
|
2 | 2 | SMF2SEG | 2 | binary | Segment descriptor (see record length field).
|
4 | 4 | SMF2FLG | 1 | binary | System indicator: Bit Meaning When Set 0-2 Reserved 3-6 Version indicators* 7 Reserved.*See “Standard SMF Record Header” on page 13-1 for a detailed description.
|
5 | 5 | SMF2RTY | 1 | binary | Record type 2 (X'02').
|
6 | 6 | SMF2TME | 4 | binary | Time since midnight, in hundredths of a second, when the record was moved into the dump data set.
|
10 | A | SMF2DTE | 4 | packed | Date when the record was moved into the dump date set, in the form 0cyydddF. See “Standard SMF Record Header” on page 13-1 for a detailed description.
|
14 | E | SMF2SID | 4 | EBCDIC | System identification (from the SID parameter).
|
The table above is based on the description provided by IBM in its "MVS Systems Management Facilities (SMF)" manual.
Home |
Products |
Prices |
Documentation |
30-Day Trials |
Customer Reviews |
Company
| FAQ
| Sample Reports
| SMF Records