Spectrum SMF Writer - the 4GL SMF Report Writer.

SMF Type 53 Record

This table shows the record layout for type 53 SMF records
(JES2 LOGOFF/Stop Line (SNA only)).

List of other SMF record layouts available.
List of sample SMF reports.

Purpose: Record type 53 is written when:

  • A $P LNEn command (to stop a line) is issued
  • A $E LNEn command (to restart a line) is issued
  • When a remote user signs off.

This record contains:

  • A record indicator
  • A remote name
  • A line name
  • A password
  • A line adapter address
  • The number of execute channel programs (EXCP)
  • Negative acknowledgements to write text
  • Data checks to read text
  • Time outs to read text.

It's easy to report on SMF 53 data!

SMF Spectrum Writer
We have a low-cost 4GL report writer especially for SMF files. It's called Spectrum SMF Writer.

Spectrum SMF Writer handles the difficult SMF record parsing for you automatically. You just specify which fields you want to see.

Spectrum SMF Writer also converts the arcane date and time fields and reformats them into an attractive report.

Plus, Spectrum SMF Writer can export SMF data as comma delimited files to use on your PC.
 
Try It FREE Now!

SMF Type 53 Record -- JES2 LOGOFF/Stop Line (SNA only)
Offset
(Dec.)
Offset
(Hex)
NameLengthFormatDescription
00SMF53LEN2binary
Record length. This field and the next field (total of four bytes) form the RDW (record descriptor word). See “Standard SMF Record Header” on page 13-1 for a detailed description.
22SMF53SEG2binary
Segment descriptor (see record length field).
44SMF53FLG1binary
System indicator: Bit Meaning When Set 0-2 Reserved 3-6 Version indicators* 7 Reserved.*See “Standard SMF Record Header” on page 13-1 for a detailed description.
55SMF53RTY1binary
Record type 53 (X'35').
66SMF53TME4binary
Time since midnight, in hundredths of a second, that the record was moved into the SMF buffer.
10ASMF53DTE4packed
Date when the record was moved into the SMF buffer, in the form 0cyydddF. See “Standard SMF Record Header” on page 13-1 for a detailed description.
14ESMF53SID4EBCDIC
System identification (from the SID parameter).
1812SMF53PRD2binary
Offset to product section from start of record, including record descriptor word (RDW).
2014SMF53PRL2binary
Length of product section.
2216SMF53PRN2binary
Number of product section.
2418SMF53IDO2binary
Offset to identification section from start of record, including record descriptor word (RDW).
261ASMF53IDL2binary
Length of identification section.
281CSMF53IDN2binary
Number of identification section.
301ESMF53SUB2binary
Subtype ID 1 = Record written for LOGOFF 2 = Record written for LNEn.
3220SMF53VER2EBCDIC
Record version number.
3422SMF53SYS4EBCDIC
Subsystem name, ‘JES2’.
3826SMF53RMT8EBCDIC
Remote name as defined in JESPARMS.
462ESMF53LIN8EBCDIC
Line name as defined in JESPARMS.
5436SMF53PSW8EBCDIC
Line password as defined in JESPARMS.
623ESMF53CTR_
1
4binary
Number of VTAM requests processed.
6642SMF53CTR_
2
4binary
Number of exception responses.
7046SMF53CTR_
3
4binary
Number of LUSTATs received.
744ASMF53CTR_
4
4binary
Number of bid rejects.
784ESMF53CTR_
5
4binary
Number of temporary errors.
8252SMF53ADP3EBCDIC
Line identifier, ‘SNA’

The table above is based on the description provided by IBM in its "MVS Systems Management Facilities (SMF)" manual.

Copyright 2024.
Pacific Systems Group.
All rights reserved.


Spectrum Writer 4GL - the economical alternative to SAS, Easytrieve, DYL-280...

Home | Products | Prices | Documentation | 30-Day Trials | Customer Reviews | Company | FAQ | Sample Reports | SMF Records
Send Your Comments or Questions