SMF Type 57 Record

This table shows the record layout for type 57 SMF records
(JES2 Network SYSOUT Transmission).

List of other SMF record layouts available.
List of sample SMF reports.

Purpose: Record type 57 is written to record JES2 SYSOUT transmission information. This record contains original and current job identifiers, transmitter start and stop times, and a count of the records transmitted.

It's easy to report on SMF 57 data!

SMF Spectrum Writer
We have a low-cost 4GL report writer especially for SMF files. It's called Spectrum SMF Writer.

Spectrum SMF Writer handles the difficult SMF record parsing for you automatically. You just specify which fields you want to see.

Spectrum SMF Writer also converts the arcane date and time fields and reformats them into an attractive report.

Plus, Spectrum SMF Writer can export SMF data as comma delimited files to use on your PC.
 
Try It FREE Now!

SMF Type 57 Record -- JES2 Network SYSOUT Transmission
Offset
(Dec.)
Offset
(Hex)
NameLengthFormatDescription
00SMF57LEN2binary
Record length. This field and the next field (total of four bytes) form the RDW (record descriptor word). See “Standard SMF Record Header” on page 13-1 for a detailed description.
22SMF57SEG2binary
Segment descriptor (see record length field).
44SMF57FLG1binary
System indicator: Bit Meaning When Set 0-2 Reserved 3-6 Version indicators* 7 Reserved.*See “Standard SMF Record Header” on page 13-1 for a detailed description.
55SMF57RTY1binary
Record type 57 (X'39').
66SMF57TME4binary
Time since midnight, in hundredths of a second, that the record was moved into the SMF buffer.
10ASMF57DTE4packed
Date when the record was moved into the SMF buffer, in the form 0cyydddF. See “Standard SMF Record Header” on page 13-1 for a detailed description.
14ESMF57SID4EBCDIC
System identifier (from the SID parameter).
1812SMF57SBS2binary
Subsystem identifier — X'0002' signifies JES2.
2014SMF57SUB2binary
Record subtype.
2216SMF57LRR2binary
Length of rest of record, not including this field.
2418SMF57JID8EBCDIC
Original job identification.
3220SMF57CJD8EBCDIC
Current job identification.
4028SMF57ONN8EBCDIC
Original node name.
4830SMF57ENN8EBCDIC
Processing node name.
5638SMF57NNN8EBCDIC
Next node name.
6440SMF57DVN8EBCDIC
SYSOUT transmitter device name.
7248SMF57TSS4binary
SYSOUT transmitter start time.
764CSMF57DSS4packed
SYSOUT transmitter start date.
8050SMF57TPS4binary
SYSOUT transmitter stop time.
8454SMF57DPS4packed
SYSOUT transmitter stop date.
8858SMF57ACN8EBCDIC
Network account number.
9660SMF57TSI4EBCDIC
SYSOUT transmitter system identification.
10064SMF57CNT4binary
Count of logical TP records.
10468SMF57NTR2binary
Number of triplets in record. A triplet is a set of offset/length/number values that defines a section of the record.
1066A--2binary
Reserved.
1086CSMF57OSW4binary
Offset to Enhanced SYSOUT Support (ESS) section.
11270SMF57LSW4binary
Length of Enhanced SYSOUT Support (ESS) section.
11674SMF57NSW4binary
Number of Enhanced SYSOUT Support (ESS) sections.
Enhanced SYSOUT Support (ESS) Section
This section contains the output descriptor (if any) for first offloaded data set in this record.
(Offset from beginning of record: SMF57OSW)
00SMF57LN52binary
Length of ESS section (including this field).
22SMF57SGT4binary
Segment identifier.
66SMF57IND1binary
Section indicator Bit Meaning When Set 0 Error obtaining scheduler JCL facility (SJF) information. Scheduler work block text unit (SWBTU) data area is not present. 1-7 Reserved.
77--1binary
Reserved.
88SMF57JDT8EBCDIC
JCL definition table (JDT) name in JCL definition vector table (JDTV).
1610SMF57TUL2binary
Text unit (SWBTU) data area length.
1812SMF57TUVARbinary
Text unit (SWBTU) data area. The data area can be processed using the SWBTUREQ macro.

The table above is based on the description provided by IBM in its "MVS Systems Management Facilities (SMF)" manual.